RTS Room Thermostats
- Range limiting stops
- Set point locking
- Surface or conduit box mounting
- Double insulated
The RTS range of thermostats utilise electronic sensing to provide accurate temperature control. Seven models are available to suit all domestic applications including frost protection and combi boilers.
RTS1: Standard Model
RTS2 With LED 'ON' indicator
RTS3: Frost thermostat
RTS4: Volt free contacts (suitable for combi boilers)
RTS5: Energy saver room thermostat with volt free chagne over contacts
RTS9: Volt free heating/cooling change over switch with call for heat LED indicator
RTS10: Volt free heating/colling change over switch with call for heat LED indicator (Min-Max)
Technical
| Sensing element | Electronic |
| Temperature range | |
| RTS1, 2, 4, 5 & 9 | 10°C to 30°C |
RTS3
| 3°C to 10°C |
| RTS10 | 14°C to 30°C |
| Switch rating | 2(1)A 230V a.c. |
| Switch type | |
| RTS1, 2 & 3 | S.P.S.T. |
| RTS4, 9 & 10 | S.P.D.T. (volt free) |
| RTS5 | S.P.D.T. 2(1)A |
| Differential | |
| RTS1, 2, 4, 9 & 10 | <0.6°C at 4°/hour |
| RTS3 | 1°C typical |
Relevant EC Directives 2006/95/EC Low Voltage Directive 2004/108/EC Electromagnetic Compatibility DirectiveApplied Standards EN60730-1; EN60730-2-9