Tapstat Cylinder Controls

  1. You are here
  2.  Home
  3.  Products
  4.  Heating Thermostats
  5.  Cylinder and Pipe
  6.  Tapstat
Tapstat Cylinder Controls(3)
  • Self acting (non electric)
  • Range limiting stops
  • Remote sensor with 2m capillary
  • Compression fittings for copper pipe
  • Simple to install

Self-acting tapstats control domestic hot water temperatures on gravity or pumped primary systems preventing scalding and fuel wastage

Technical

Max. static pressure147 psi (10 bar)
Max. primary flow temperature100°C continuous
120°C intermitte

Max. differential pressure*

15mm 2 way    59 psi (4 bar)
15mm 3 way    29 psi (2 bar)
28mm gravity    7 psi (0.5 bar)

Kv value (fully open)

15mm 2 way     1.1
15mm 3 way     1.1
28mm gravity    4.6
Setting range32°C to 72°C