Tempus Electronic Timeswitches Discontinued
- Boost – gives an extra one or two hours operation. Available on all channels.
- Advance – manually switches from ON to OFF or vice-versa
- 12 Hour clock – easier for all age groups to understand
TEMPUS 1
A single channel timeswitch offering 24 hour or 5 day/2 day programming. Ideal for combi boilers, extra zones or any application where simple time control is required
TEMPUS 2
With the option of 5 day/2 day or 7 day programming, Tempus 2 puts added flexibility at the customers fingertips.
Where a simple but sophisticated timeswitch is required, there is no equal.
Technical
- Voltage 230V a.c.
- Rating 2(1)A 230V a.c. each switch
- Ambient temperature Operating: 0 to 45°C Storage: -20 to 50°C
Wiring - Designed for fixed wiring only, to comply with current IEE regulations
Maintenance - No user maintenance should be attempted
Designed for fixed wiring only, to comply with current IEE regulations
Relevant EC Directives 2006/95/EC Low Voltage Directive 2004/108/EC Electromagnetic Compatibility DirectiveApplied Standards: EN60730-1; EN60730-2-9