Find a Drayton stockist near you
Documents
Installation Guides
Brochures
User Guides
Specifications
- Part number
- LP111: 25477; RTS4: 24004
- Energy class
- IV = 2% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
- Software class
- A
- Applied standards
- EN60730-1; EN60730-2-7; EN60730-2-9
- Timing resolution
- 1 minute
- Ball pressure test
- 75ºC
- Setting range
- 10°C to 30°C
- Control accuracy
- <0.6ºC at 4º/hour
- Pollution degree
- 2
- Power supply
- LP111: 230V a.c. +10% -10% 50Hz; RTS4: 24-230V a.c./d.c. 50Hz fused 3A double insulated (no earth required)
- Mounting
- LP111: Industry standard wallplate; RTS4: Suitable for surface or conduit box mounting
- Wiring
- Designed for fixed wiring only, to comply with current IET wiring regulations (BS7671)
- Switch rating
- LP111: 2(1)A 230V a.c. each switch; RTS4: S.P.D.T 2(1)A 230V a.c. volt free
- Output
- Programmers; 230V a.c. Timeswitches: according to supply to common terminal - volt-free contacts
- Rated impulse voltage
- LP111: 2.5kV
- Ambient operating temperature
- LP111: 0°C to 50°C; RTS4: 0ºC to 40ºC
- Ambient storage temperature
- LP111: -20°C to 50°C; RTS4: -20°C to 55°C
- Ambient operating humidity (non condensing)
- 25 - 90%
- Ambient storage humidity
- 15 - 95%
- Relevant EC directives
- LP111: 2014/35/EU Low Voltage Directive 2014/30/EU Electromagnetic Compatibility Directive 2006/66/EC Batteries Directive 2011/65/EU RoHS Directive; RTS4: 2014/35/EU Low Voltage Directive 2014/30/EU Electromagnetic Compatibility Directive 2011/65/EU RoHS