Find a Drayton stockist near you
Documents
Brochures
User Guides
Specifications
- Dimensions
- HubR: 150.8mm (w) 94mm (h) 30.25mm (d); Room thermostat: 76mm (w) 76mm (h) 25mm (d); Radiator thermostat: 76mm (w) 76mm (h) 25mm (d)
- Power supply
- HubR: 230V a.c. ±10% 50Hz; Room thermostat: 2x 1.5v IEC LR6 (AA) alkaline batteries; Radiator thermostat: 2x 1.5v IEC LR6 (AA) alkaline batteries
- Switch rating
- 2A resistive 230V a.c. each switch (not suitable for inductive loads)
- Wiring
- HubR: Fixed wiring only, to comply with current IET regulations (BS7671); Room thermostat: No wiring required; Radiator thermostat: No wiring required
- Interfaces
- HubR: Push Button/LED; I/O: Mains Relays (1-3), Digital Boiler Interface; Room thermostat: TFT display, touch buttons; I/O: None; Radiator thermostat: Twist Cap, LED; I/O: None
- Operating temperature
- HubR: 0°C to 45°C; Room thermostat: 0°C to 45°C; Radiator thermostat: -20°C to 65°C
- Storage temperature
- HubR: -20°C to 65°C; Room thermostat: -10°C to 55°C; Radiator thermostat: -10°C to 55°C
- Maximum mounting surface temperature
- 93°C
- Maximum water temperature
- 73°C continuous and 110°C max
- Ingress protection
- HubR: IP30; Room thermostat: IP20; Radiator thermostat: IP30
- Ambient humidity (non-condensing)
- HubR: 25% to 90%; Room thermostat & Radiator thermostat: Operating 25% to 90%, Storage 15% to 95%
- Setpoint range
- 5°C to 30°C
- Control accuracy
- <0.6°C at 4°C/hour (with Room Thermostat) <0.8°C at 4°C/hour (with Radiator Thermostat)
- Timing resolution
- 1 minute
- Temperature resolution
- 0.5°C
- Ball pressure test
- HubR: 92°C; Room thermostat & Radiator thermostat: 75°C
- Pollution degree
- 2
- Software class
- A
- Without mains power
- HubR: Display: LEDs off; Time: always kept; Programme times: always preserved
- Rated impulse voltage
- 2.5kV EU/UK, 4kV DE
- Radio technology/frequency
- HubR: Wi-Fi: 2.4 GHz, IEEE802.11 b/g/n Zigbee: 2.4 GHz, IEEE802.15.4; Room thermostat: Zigbee: 2.4 GHz, IEEE802.15.4
- Radio signal range
- Max 30m in free air
- Mounting
- HubR: Wall plate; Room thermostat: Wall bracket or desk stand; Radiator thermostat: Radiator valve
- Maximum radio frequency power transmitted
- HubR: Wi-Fi: +17dBm (16 mW) Zigbee: +12dBm (50 mW); Room thermostat & Radiator thermostat: +13dBm (20mW)
- Relevant directives
- Radio Equipment Directive (RED) 2014/53/EU & Commission Delegated Regulation (EU) 2022/30 (RED DA), Batteries Directive 2006/66/EC, RoHS Directive 2011/65/EU
- Applied standards
- EN IEC 63000; EN IEC 62311; EN 60730-1; EN 301 489-17; EN 60730-2-7; EN 300 328; EN60730-2-9
Videos
Wiser 2nd Generation Smart Heating System | Smart Thermostats | Smart Radiator Thermostats | Wiser